You must be logged in to post a review.
DHT11 (Temperature and Humidity Sensor Module)
DHT11 Temperature and Humidity Sensor Module with LED Power Supply Indicators
Features:
- Can detect surrounding environment of the humidity and temperature
- DHT11 sensor adopts
- Humidity measurement range: 20%-95%, humidity measurement error: +-5%
- Temperature measurement range: 0 -50 ;measurement error: +-2 degrees
- Working voltage 3.3 V-5 V
- Output form: digital output
- Has fixed bolt hole and easy installation
- PCB size: 3.1cm x 1.4cm
Categories: Sensor Modules, Temperature Sensor Modules
Related products
AMG8834
Temperature Sensor Digital, Infrared (IR) 14-SMD Module
Product Specifications
Sensor type | Infrared array sensor | |
Maximum output current | 10mA | |
Sensing distance | 7m | |
Switch mode | digital | |
Installation type | Surface mount | |
Number of pins | 14 | |
Maximum supply current | 4.5 mA | |
size | 11.6 x 8 x 4.3mm | |
height | 4.3mm | |
length | 11.6mm | |
series | Grid-EYE | |
Maximum working temperature | +80 °C | |
Maximum operating supply voltage | 5 V DC | |
Minimum operating temperature | -20 °C | |
width | 8mm |
CJMCU-175 (Digital Temperature Sensor Module)
General Features:
CJMCU-175 Digital Temperature Sensor TMP175 27 Address
Digital output: SMBusTM, two-wire and I2C interface compatibility
Resolution: 9 to 12 digits, user selectable
Wide supply voltage range: 2.7V to 5.5V
TMP175 allowing up to 27 devices on a bus member.
It is a negative temperature desired coefficient thermistor (NTC) and positive temperature coefficient (PTC) for generation
The device provides a typical ±1°C accuracy without calibration or external component signal conditioning .
The on-chip 12-bit analog -to- digital converter (ADC) provides resolution down to 0.0625°C.
MQ-135 (Air Quality Control Gas Sensor)
MQ-4 (Methane Gas Sensor module for Arduino)
MQ-6 LPG Gas Sensor Module
This is a simple-to-use liquefied petroleum gas (LPG) sensor, suitable for sensing LPG (composed of mostly propane and butane) concentrations in the air. The MQ-6 can detect gas concentrations anywhere from 300 to 10000ppm. This sensor has a high sensitivity and fast response time. The sensor’s output is an analog resistance. The drive circuit is very simple; all you need to do is power the heater coil with 5V, add a load resistance, and connect the output to an ADC.
Sharp IR Long Range Sensor – 20 cm to 150 cm
- Infrared range finder 20cm(~8") to 150cm (~60")