ML8511 (Analog Output Ultraviolet Sensor)
Features:
- Optical sensor to UV-A and UV-B
- Realize equalization of an output voltage by trimming
- The analog voltage output proportional to UV light intensity
- Low current operation ( 300µA Typ. ) and low standby current ( 0.1µA Typ. )
- The TSV-CSP version is under development for the further small size package( 2.1 × 1.8mm )
Categories: Sensor Modules, Ultraviolet Ray Sensor Modules
Description
Description:
The ML8511 breakout is an ultraviolet light sensor which is easy to use. The MP8511 UV (ultraviolet) Sensor works by outputing an analog signal in relation to the amount of UV light that’s tested. This breakout can be very handy in creating devices that warn the user of sunburn or test the UV index as it relates to weather conditions.
The range of the most effective light tested by the sensor is 280-390nm. This is categorized as part of the UVB (burning rays) spectrum and most of the UVA (tanning rays) spectrum. It outputs an analog voltage that is linearly related to the measured UV intensity (mW / cm2). If your microcontroller can do an analog to digital signal conversion then you can test the level of UV!
ML8511 UV light can be used with an analog voltage output proportional to the amount. Since the output voltage can therefore be directly connected to the MCU built A / D digital / analog converter, no photoelectric converting circuit. And the use of small, low-profile surface-mount package, suitable for use in portable devices.
Features:
- Optical sensor to UV-A and UV-B
- Realize equalization of an output voltage by trimming
- The analog voltage output proportional to UV light intensity
- Low current operation ( 300µA Typ. ) and low standby current ( 0.1µA Typ. )
- The TSV-CSP version is under development for the further small size package( 2.1 × 1.8mm )
Applications:
- Wireless PC peripherals
- UV skin care monitor of ageing etc
- As a sensor network node in sunshine and environment monitor
- Industrial usues such as sterilization and washing
- As a UV monitor of mobile computing device such as
- Smart phones
- Mobile phones
- Games
- Mobile accessories
- Watch
Pinouts
- VIN : Power Connection (3V – 5V)
- 3.3V : Output of the on board regulator
- GND: 0V
- OUT: Analog Output
- EN: Enable Input
Reviews (0)
Be the first to review “ML8511 (Analog Output Ultraviolet Sensor)” Cancel reply
You must be logged in to post a review.
Shipping & Delivery
Related products
CJ1WTS562 (Temperature Sensor Module Screw Terminal Connection)
Omron Temperature sensor module is suitable for use with cj1 series programmer controllers
Highlights/Features:
Omron Temperature sensor module is suitable for use with cj1 series programmer controllers These temperature sensor units are classified as digital I/O units when considering I/O allocations and will take digital I/O points from the total allocation for a CJ1M CPU. The number of I/O points is DIP switch selectable as follows; configured for 1 - 3 inputs takes 48 digital I/O points, configured for 4 inputs takes 64 digital I/O points and configured for 5 - 6 inputs takes 96 digital I/O points.DHT11 (Temperature and Humidity Sensor Module)
DHT11 Temperature and Humidity Sensor Module with LED Power Supply Indicators
Features:
- Can detect surrounding environment of the humidity and temperature
- DHT11 sensor adopts
- Humidity measurement range: 20%-95%, humidity measurement error: +-5%
- Temperature measurement range: 0 -50 ;measurement error: +-2 degrees
- Working voltage 3.3 V-5 V
- Output form: digital output
- Has fixed bolt hole and easy installation
- PCB size: 3.1cm x 1.4cm
MQ-7 (Carbon Monoxide Gas Sensor Module)
MQ-7 Carbon Monoxide Gas Sensor Module is used to detect Carbon Monoxide (CO) concentration, it can detect CO-gas concentrations anywhere from 20 to 2000ppm. This sensor has a high sensitivity and fast response time. The module outputs a voltage from 0 to 5V relative to the CO concentration. The sensor can operate at temperatures from -10 to 50°C and consumes less than 150 mA at 5 V.
MQ-8 (Hydrogen Gas Sensor Module)
MQ-8 Sensor Information: sensitive material MQ- 8 gas sensors used in clean air, low conductivity tin oxide (SnO2). When there is an environment in which the combustible gas sensor, conductivity sensor with increasing concentration of combustible gases in air increases. Use simple circuit can convert the change in conductivity of the gas concentration corresponding to the output signal. MQ-8 hydrogen gas sensor of high sensitivity monitoring of other hydrogen-containing gas is also very good. The sensor can detect a variety of hydrogen-containing gas, in particular, city gas, is a low-cost sensor suitable for a variety of applications.
TCS34725 (RGB Color Sensor with IR filter and White LED)
OVERVIEW:
1. Red, Green, Blue (RGB), and White Light Sensing with IR Blocking Filter
2. Programmable Analog Gain and Integration Time
3. 3,800,000:1 Dynamic Range
4. Very High Sensitivity: Ideally Suited for Operation Behind Dark Glass
5. Maskable Interrupt
6. Programmable Upper and Lower Thresholds with Persistence Filter
7. Power Management
8. Low Power: 2.5-uA Sleep State
9. 65-uA Wait State with Programmable Wait State Time from 2.4 ms to > 7 Seconds
10. I2C Fast Mode Compatible Interface
11. Data Rates up to 400 kbit/s
12. Input Voltage Levels Compatible with VDD or 1.8 V Bus
13. Register Set and Pin Compatible with the TCS3x71 Series
14. Small 2 mm*2.4 mm Dual Flat No-Lead (FN)
TMP006 (Contact-less Infrared Temperature Measurement)
The TMP006 works with 3v to 5v, so it can be used with most microcontrollers without the need for a level shifter. It connects via the i2c bus and is addressable so you can have up to 8 TMP006 sensors on the same bus.
Features:
- 20mm x 20mm (board w/o headers)
- Uses I2C 7-bit addresses between 0x40 and 0x47, selectable with jumpers
- Interface Type : I2C Arduino driver module
TTP229-LSF (Capacitive Touch Keypad Module)
Features:
- On board 8 capacitive touch keys and 1 linear capacitive sensor
- Features TONTEK TonTouch touch pad detector IC TTP229-LSF, supports up to 16 keys with adjustable sensitivity and built-in LDO
- The system recalibrates automatically when all keys are not detected touch more than about 4 seconds
- Customizable functions:
- 8 keys or 16 keys option
- 8 individual outputs or batch production
- Single-key or multi-kye feature
- Sampling rate and duration of sampling in sleep mode
- The maximum key is on time